This is what Sonterra MUD reported to the state and EPA. It is not a test of the water at your tap, which your home's pipes and fixtures can change. Information only, not medical advice. Data sources and method
Depth Score · partial
Below limits, some above health goals
TapDepth's rating of public data, not a safety finding. As of Nov 2026, method 1.2. How the score works
From results reported by Sonterra MUD, sampled Dec 2024 to Sep 2026. Not a test of your tap.
- Health55%94
- Pipes20%Not included
Not in our data yet: utilities' lead service line inventories haven't been added.
- Track record15%59
- Everyday water10%Not included
No recent hardness or dissolved solids results.
How this score was worked out
Health
Each substance's average over its latest year of samples, compared with its legal limit and health goal. Up to 10 points off each. Volatile organic chemicals count as one group, by the worst one, and so do pesticides and industrial chemicals, and nitrate with nitrate + nitrite. Lead and copper use the 90th percentile of home tap samples and the action level.
| Substance | Average | Legal limit | Health goal | Rule | Points |
|---|---|---|---|---|---|
| Arsenic | 2.1 µg/L (2 samples, Jul 2026 to Jul 2026) | 10 µg/L | 0 µg/L (EPA health goal (MCLG)) | Health goal is zero | −3.7 |
| Nitrate (as nitrogen) | 0.119 mg/L (10 samples, Oct 2025 to Sep 2026) | 10 mg/L | 10 mg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Fluoride | 1.29 mg/L (8 samples, Nov 2025 to Sep 2026) | 4 mg/L | 4 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Benzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Carbon tetrachloride | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichlorobenzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 600 µg/L | 600 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,4-Dichlorobenzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 75 µg/L | 75 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichloroethane | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1-Dichloroethylene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 7 µg/L | 7 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| cis-1,2-Dichloroethylene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 70 µg/L | 70 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| trans-1,2-Dichloroethylene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Dichloromethane | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichloropropane | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Ethylbenzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 700 µg/L | 700 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Chlorobenzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Styrene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Tetrachloroethylene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Toluene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 1,000 µg/L | 1,000 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2,4-Trichlorobenzene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 70 µg/L | 70 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1,1-Trichloroethane | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 200 µg/L | 200 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1,2-Trichloroethane | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 3 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Trichloroethylene | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Vinyl chloride | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 2 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Xylenes (total) | 0 µg/L (1 sample, Jan 2025 to Jan 2025) | 10,000 µg/L | 10,000 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Antimony | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 6 µg/L | 6 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Barium | 0.0407 mg/L (2 samples, Jul 2026 to Jul 2026) | 2 mg/L | 2 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Beryllium | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 4 µg/L | 4 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Cadmium | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 5 µg/L | 5 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Chromium (total) | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Cyanide | 35 µg/L (2 samples, Jul 2026 to Jul 2026) | 200 µg/L | 200 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Mercury (inorganic) | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 2 µg/L | 2 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Nitrite (as nitrogen) | 0 mg/L (1 sample, Jan 2025 to Jan 2025) | 1 mg/L | 1 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Selenium | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 50 µg/L | 50 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Thallium | 0 µg/L (2 samples, Jul 2026 to Jul 2026) | 2 µg/L | 0.5 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Nitrate + nitrite (as nitrogen) | 0.35 mg/L (1 sample, Jan 2025 to Jan 2025) | 10 mg/L | 10 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Lead | 0.431 µg/L (1 sample, Dec 2024 to Dec 2024) | 15 µg/L | 0 µg/L (EPA health goal (MCLG)) | Health goal is zero | −2.2 |
Track record
100, minus 25 for each health-based violation in the last 5 years (here 0), 10 for each from 5 to 10 years ago (2) and 3 for each missed or late test, report or notice (7). Boil water notices aren't in our data yet.
Everyday water
No recent hardness or dissolved solids results.
PFAS
PFAS are not counted until EPA's PFAS limits take effect. EPA currently lists April 2029 for PFOA and PFOS, and has proposed moving that to 2031. PFAS results are shown separately.
PFAS outlook: upcoming EPA limits
Not yet enforceable. EPA lists April 2029 and has proposed 2031.
PFOA and PFOS were not detected (below the lab's reporting limit) in the latest year of samples in our data.
Latest sample October 21, 2024. Highest sample point one-year average, counted the rule's way: 0 ng/L (6 samples at 3 sample points, Apr 2024 to Oct 2024).
Latest sample October 21, 2024. Highest sample point one-year average, counted the rule's way: 0 ng/L (6 samples at 3 sample points, Apr 2024 to Oct 2024).
Bars show the latest sample. The line marks EPA's upcoming limit of 4 ng/L each.
Reported by Sonterra MUD, sampled October 21, 2024.
Averaged the way EPA's rule describes (each sample point's one-year average), using the results we have. The rule counts results below 4 ng/L (parts per trillion) as zero in that average. Our data may not include every sample point, and only regulators decide compliance.
The PFAS outlook is not a compliance finding and does not change the Depth Score. It covers PFOA and PFOS, the two PFAS limits EPA has said it plans to keep. Results from untreated source water are left out.
substances with a recent sample
in the latest samples
since Nov 2016
paperwork and monitoring, since Nov 2016
Current results
36 substancesSubstances with drinking water limits, from the last six years of samples. Highest recent sample shown.
- Arsenic2.2 µg/LReported by Sonterra MUD, sampled July 7, 2026.EPA's health goal for this substance is zero.Sample point: point EP002 TRT-TAPWhat is arsenic?
- Nitrate (as nitrogen)Not detected (below 0.25 mg/L)Reported by Sonterra MUD, sampled September 10, 2026.Sample point: point EP001 TRT-TAPWhat is nitrate?
- Fluoride1.41 mg/LReported by Sonterra MUD, sampled September 10, 2026.Sample point: point EP001 TRT-TAPWhat is fluoride?
- BenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is benzene?
- Carbon tetrachlorideNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is carbon tetrachloride?
- 1,2-DichlorobenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,2-Dichlorobenzene?
- 1,4-DichlorobenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,4-Dichlorobenzene?
- 1,2-DichloroethaneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,2-Dichloroethane?
- 1,1-DichloroethyleneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,1-Dichloroethylene?
- cis-1,2-DichloroethyleneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is cis-1,2-Dichloroethylene?
- trans-1,2-DichloroethyleneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is trans-1,2-Dichloroethylene?
- DichloromethaneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is dichloromethane?
- 1,2-DichloropropaneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,2-Dichloropropane?
- EthylbenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is ethylbenzene?
- ChlorobenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is chlorobenzene?
- StyreneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is styrene?
- TetrachloroethyleneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is tetrachloroethylene?
- TolueneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is toluene?
- 1,2,4-TrichlorobenzeneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,2,4-Trichlorobenzene?
- 1,1,1-TrichloroethaneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,1,1-Trichloroethane?
- 1,1,2-TrichloroethaneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is 1,1,2-Trichloroethane?
- TrichloroethyleneNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is trichloroethylene?
- Vinyl chlorideNot detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is vinyl chloride?
- Xylenes (total)Not detected (below 0.5 µg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is xylenes?
- AntimonyNot detected (below 1 µg/L)
- Barium0.0438 mg/L
- BerylliumNot detected (below 0.8 µg/L)
- CadmiumNot detected (below 1 µg/L)
- Chromium (total)Not detected (below 10 µg/L)Reported by Sonterra MUD, sampled July 7, 2026.Total chromium includes chromium-3 and chromium-6. EPA's 100 µg/L limit covers the total, and there's no separate federal limit for chromium-6.Sample point: point EP001 TRT-TAPWhat is chromium (total)?
- Cyanide70 µg/L
- Mercury (inorganic)Not detected (below 0.4 µg/L)
- Nitrite (as nitrogen)Not detected (below 0.05 mg/L)Reported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is nitrite?
- SeleniumNot detected (below 3 µg/L)
- ThalliumNot detected (below 0.4 µg/L)
- Nitrate + nitrite (as nitrogen)0.35 mg/LReported by Sonterra MUD, sampled January 23, 2025.Sample point: point EP002 TRT-TAPWhat is nitrate + nitrite?
- Lead0.431 µg/LReported by Sonterra MUD, sampled December 31, 2024.EPA's health goal for this substance is zero.Sample point: 90th percentile of home tap samples the system collected, Jan 2022 to Dec 2024What is lead?
PFAS ("forever chemicals")
29 substancesEPA set limits for some PFAS in 2024. They aren't enforceable yet, so they're shown as upcoming limits and never in warning colors.
- PFOANot detected (below 4 ng/L)
- PFOSNot detected (below 4 ng/L)
- PFHxSNot detected (below 3 ng/L)
- PFNANot detected (below 4 ng/L)
- HFPO-DA (GenX)Not detected (below 5 ng/L)
- PFBS4.1 ng/L
- PFBANot detected (below 5 ng/L)
- PFPeA6.9 ng/LReported by Sonterra MUD, sampled October 21, 2024.Sample point: IH-35 Master MeterWhat is other PFAS?
- PFHxA3 ng/LReported by Sonterra MUD, sampled October 21, 2024.Sample point: IH-35 Master MeterWhat is other PFAS?
- PFHpANot detected (below 3 ng/L)
- PFDANot detected (below 3 ng/L)
- PFUnANot detected (below 2 ng/L)
- PFDoANot detected (below 3 ng/L)
- PFTrDANot detected (below 7 ng/L)
- PFTANot detected (below 8 ng/L)
- PFPeSNot detected (below 4 ng/L)
- PFHpSNot detected (below 3 ng/L)
- PFMPANot detected (below 4 ng/L)
- PFMBANot detected (below 3 ng/L)
- PFEESANot detected (below 3 ng/L)
- NFDHANot detected (below 20 ng/L)
- ADONANot detected (below 3 ng/L)
- 9Cl-PF3ONSNot detected (below 2 ng/L)
- 11Cl-PF3OUdSNot detected (below 5 ng/L)
- 4:2 FTSNot detected (below 3 ng/L)
- 6:2 FTSNot detected (below 5 ng/L)
- 8:2 FTSNot detected (below 5 ng/L)
- NEtFOSAANot detected (below 5 ng/L)
- NMeFOSAANot detected (below 6 ng/L)
Other monitored substances
2 substancesSubstances EPA asked systems to test for to decide future rules. Most have no limit yet.
- Lithium23.3 µg/L
- Sodium42.3 mg/L
Taste, smell and look
7 substancesGuidelines for taste and appearance. These are not health limits.
- Aluminum0.078 mg/L
- Chloride42 mg/L
- Iron0.027 mg/L
- Manganese0.0012 mg/L
- SilverNot detected (below 0.01 mg/L)
- Sulfate45 mg/L
- Zinc0.0087 mg/L
These figures were reported by the water system to its regulators. They are not a test of the water at this address. Compliance is judged on averages over time, so one sample above a limit does not by itself mean a system is out of compliance. For a test of your own tap, use a state-certified laboratory. Units: ng/L is nanograms per liter, the same as parts per trillion (ppt); µg/L is micrograms per liter, the same as parts per billion (ppb); mg/L is milligrams per liter, the same as parts per million (ppm).
Violations since Nov 2016
Recorded by the state and EPAHealth-based
A drinking water limit or treatment requirement was not met.
- Violation recorded by the state for Apr 2017 to Jun 2017Fluoride · Inorganic Chemicals · Status: resolved
- Violation recorded by the state for Jan 2017 to Mar 2017Fluoride · Inorganic Chemicals · Status: resolved
Testing and reporting
A required test or report was missed or late. This is about paperwork and monitoring, and does not by itself mean the water was unsafe.
- Missed or late test or report (Dec 2024 to Feb 2025). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Apr 2024 to Jun 2024). Doesn't by itself mean the water was unsafeChlorine · Stage 1 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Mar 2023). Doesn't by itself mean the water was unsafeChlorine · Stage 1 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Jul 2018 to Dec 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jul 2018 to Dec 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jul 2018 to Dec 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
Notices and other requirements
A required notice to customers was missed or late.
- Public Notification Violation for NPDWR Violation (Jul 2024 to Aug 2024)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
On the map
Nearby water providers, colored by Depth ScoreLoading the map…
Open on the mapYearly water quality report
We don't have a link to this provider's yearly water quality report yet. Providers that serve homes send one to customers every year by July 1, and you can ask the provider for a copy.
Where the water comes from
Sonterra MUD buys water from:
- Lone Star RwaTX2460172
When this system has no result of its own for a substance, we show its supplier's and say so.
Service lines (pipes from the water main to buildings)
As reported by SONTERRA MUD to Texas, in EPA's records as of the third quarter of 2026: 0 lead, 0 galvanized needing replacement, 0 material not yet identified, 4,029 non-lead.
Galvanized needing replacement: galvanized lines that are or were connected to lead pipe, which the rule says must be replaced.
Non-lead counts may be incomplete: EPA doesn't require them until November 2027.
A lead or galvanized service line can add lead to water, but it doesn't mean there is lead in your water. These counts cover the whole system, not your address. Ask your water system whether your home's line is on its inventory.
U.S. EPA, SDWIS/Fed Service Line Inventory report, data as of November 21, 2026
Historical results (2012-2019)
Lab results states sent EPA for 2012-2019, compiled by EPA for its Six-Year Review of drinking water rules, not for compliance decisions. They are more than six years old, so they may not reflect the water today, and they are never mixed with current results.
- ArsenicLatest: 2.9 µg/L · 1 of 4 samples detected · highest 2.9 µg/L (December 6, 2019) · legal limit 10 µg/LHistorical result, sampled December 6, 2019. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by Texas to EPA.
- Nitrate (as nitrogen)Latest: not detected · 10 of 11 samples detected · highest 0.26 mg/L (August 23, 2019) · legal limit 10 mg/LHistorical result, sampled December 6, 2019. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by Texas to EPA.
- FluorideLatest: 4.03 mg/L · 15 of 15 samples detected · highest 4.59 mg/L (June 13, 2017) · legal limit 4 mg/LWas above the legal limit in this sample (June 13, 2017).Historical result, sampled December 6, 2019. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by Texas to EPA.
- Total trihalomethanesLatest: not detected · 6 of 7 samples detected · highest 32.9 µg/L (June 13, 2017) · legal limit 80 µg/LHistorical result, sampled August 23, 2019. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by Texas to EPA.
Sources
Data refreshed November 14, 2026- Safe Drinking Water Information System (SDWIS/Fed), ECHO downloadsUS EPA, Safe Drinking Water Information System (SDWIS/Fed), via ECHO
- Service Line Inventory report (SDWIS Federal Reporting Services)U.S. EPA, SDWIS/Fed Service Line Inventory report
- Six-Year Review 4 compliance monitoring data (2012-2019)U.S. EPA, Six-Year Review 4 compliance monitoring data (2012-2019), as reported by state drinking water programs
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence dataUS EPA, UCMR 5 occurrence data
- Drinking Water Viewer: sample results (exported by hand)Texas Commission on Environmental Quality, Drinking Water Viewer data
No government agency endorses TapDepth. See something wrong? Contact us