Water report

Riverside Harbor

What this water provider reported to regulators. Public data, not a test of your tap.

Embed on your site

System ID (EPA)
TX2360014
State
Texas
Serves
363 people
Type
Community water system

This is what Riverside Harbor reported to the state and EPA. It is not a test of the water at your tap, which your home's pipes and fixtures can change. Information only, not medical advice. Data sources and method

90of 100

Depth Score · partial

Well below limits

TapDepth's rating of public data, not a safety finding. As of Nov 2026, method 1.2. How the score works

From results reported by Riverside Harbor, sampled Jun 2024 to May 2026. Not a test of your tap.

How this score was worked out

Health

Each substance's average over its latest year of samples, compared with its legal limit and health goal. Up to 10 points off each. Volatile organic chemicals count as one group, by the worst one, and so do pesticides and industrial chemicals, and nitrate with nitrate + nitrite. Lead and copper use the 90th percentile of home tap samples and the action level.

SubstanceAverageLegal limitHealth goalRulePoints
Arsenic0 µg/L (1 sample, Oct 2025 to Oct 2025)10 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goal0
Nitrate (as nitrogen)0 mg/L (2 samples, Oct 2025 to May 2026)10 mg/L10 mg/L (EPA health goal (MCLG))At or below the health goal0
Fluoride0.9 mg/L (1 sample, Jun 2024 to Jun 2024)4 mg/L4 mg/L (EPA health goal (MCLG))At or below the health goal0
Benzene0 µg/L (1 sample, May 2026 to May 2026)5 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goal0
1,2-Dichlorobenzene0 µg/L (1 sample, May 2026 to May 2026)600 µg/L600 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
1,4-Dichlorobenzene0 µg/L (1 sample, May 2026 to May 2026)75 µg/L75 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
1,2-Dichloroethane0 µg/L (1 sample, May 2026 to May 2026)5 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
cis-1,2-Dichloroethylene0 µg/L (1 sample, May 2026 to May 2026)70 µg/L70 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
trans-1,2-Dichloroethylene0 µg/L (1 sample, May 2026 to May 2026)100 µg/L100 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
Dichloromethane0 µg/L (1 sample, May 2026 to May 2026)5 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
1,2-Dichloropropane0 µg/L (1 sample, May 2026 to May 2026)5 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
Chlorobenzene0 µg/L (1 sample, May 2026 to May 2026)100 µg/L100 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
1,2,4-Trichlorobenzene0 µg/L (1 sample, May 2026 to May 2026)70 µg/L70 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
1,1,2-Trichloroethane0 µg/L (1 sample, May 2026 to May 2026)5 µg/L3 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
Trichloroethylene0 µg/L (1 sample, May 2026 to May 2026)5 µg/L0 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
Xylenes (total)0 µg/L (1 sample, May 2026 to May 2026)10,000 µg/L10,000 µg/L (EPA health goal (MCLG))At or below the health goalNot counted (group)
Antimony0 µg/L (1 sample, Oct 2025 to Oct 2025)6 µg/L6 µg/L (EPA health goal (MCLG))At or below the health goal0
Barium0.0157 mg/L (1 sample, Oct 2025 to Oct 2025)2 mg/L2 mg/L (EPA health goal (MCLG))At or below the health goal0
Beryllium0 µg/L (1 sample, Oct 2025 to Oct 2025)4 µg/L4 µg/L (EPA health goal (MCLG))At or below the health goal0
Cadmium0 µg/L (1 sample, Oct 2025 to Oct 2025)5 µg/L5 µg/L (EPA health goal (MCLG))At or below the health goal0
Chromium (total)0 µg/L (1 sample, Oct 2025 to Oct 2025)100 µg/L100 µg/L (EPA health goal (MCLG))At or below the health goal0
Cyanide0 µg/L (1 sample, May 2026 to May 2026)200 µg/L200 µg/L (EPA health goal (MCLG))At or below the health goal0
Mercury (inorganic)0 µg/L (1 sample, Oct 2025 to Oct 2025)2 µg/L2 µg/L (EPA health goal (MCLG))At or below the health goal0
Selenium0 µg/L (1 sample, Oct 2025 to Oct 2025)50 µg/L50 µg/L (EPA health goal (MCLG))At or below the health goal0
Thallium0 µg/L (1 sample, Oct 2025 to Oct 2025)2 µg/L0.5 µg/L (EPA health goal (MCLG))At or below the health goal0
Lead0.735 µg/L (1 sample, Dec 2025 to Dec 2025)15 µg/L0 µg/L (EPA health goal (MCLG))Health goal is zero−2.4

Track record

100, minus 25 for each health-based violation in the last 5 years (here 1), 10 for each from 5 to 10 years ago (0) and 3 for each missed or late test, report or notice (4). Boil water notices aren't in our data yet.

Everyday water

No recent hardness or dissolved solids results.

PFAS

PFAS are not counted until EPA's PFAS limits take effect. EPA currently lists April 2029 for PFOA and PFOS, and has proposed moving that to 2031. PFAS results are shown separately.

PFAS outlook: upcoming EPA limits

Not yet enforceable. EPA lists April 2029 and has proposed 2031.

Not tested yet

We don't have PFOA or PFOS results for this system. EPA's national PFAS sampling covered mostly larger systems, and other results may not be public yet. This doesn't mean PFAS were or weren't found. Under EPA's rule, community water systems must finish initial PFAS testing by 2027.

The PFAS outlook is not a compliance finding and does not change the Depth Score. It covers PFOA and PFOS, the two PFAS limits EPA has said it plans to keep. Results from untreated source water are left out.

Current results34

substances with a recent sample

Above a legal limit0

in the latest samples

Health-based violations1

since Nov 2016

Missed or late tests2

paperwork and monitoring, since Nov 2016

Current results

26 substances

Substances with drinking water limits, from the last six years of samples. Highest recent sample shown.

Other monitored substances

1 substance

Substances EPA asked systems to test for to decide future rules. Most have no limit yet.

Taste, smell and look

7 substances

Guidelines for taste and appearance. These are not health limits.

These figures were reported by the water system to its regulators. They are not a test of the water at this address. Compliance is judged on averages over time, so one sample above a limit does not by itself mean a system is out of compliance. For a test of your own tap, use a state-certified laboratory. Units: µg/L is micrograms per liter, the same as parts per billion (ppb); mg/L is milligrams per liter, the same as parts per million (ppm).

Violations since Nov 2016

Recorded by the state and EPA

Health-based

A drinking water limit or treatment requirement was not met.

  • Violation recorded by the state for Oct 2024 to May 2025LEAD AND COPPER RULE REVISIONS · Lead and Copper Rule Revisions · Status: resolved

Testing and reporting

A required test or report was missed or late. This is about paperwork and monitoring, and does not by itself mean the water was unsafe.

  • Missed or late test or report (Oct 2024 to May 2025). Doesn't by itself mean the water was unsafeLEAD AND COPPER RULE REVISIONS · Lead and Copper Rule Revisions · Status: resolved
  • Missed or late test or report (Oct 2021 to Sep 2022). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved

Notices and other requirements

A required notice to customers was missed or late.

  • Public Notification Violation for NPDWR Violation (May 2025 to Jun 2025)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
  • Public Notification Violation for NPDWR Violation (Dec 2022 to Feb 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved

On the map

Nearby water providers, colored by Depth Score

Loading the map…

Open on the map

Yearly water quality report

We don't have a link to this provider's yearly water quality report yet. Providers that serve homes send one to customers every year by July 1, and you can ask the provider for a copy.

Where the water comes from

No water purchases from another system are recorded.

Service lines (pipes from the water main to buildings)

As reported by RIVERSIDE HARBOR to Texas, in EPA's records as of the third quarter of 2026: 0 lead, 0 galvanized needing replacement, 0 material not yet identified, 132 non-lead.

Galvanized needing replacement: galvanized lines that are or were connected to lead pipe, which the rule says must be replaced.

Non-lead counts may be incomplete: EPA doesn't require them until November 2027.

A lead or galvanized service line can add lead to water, but it doesn't mean there is lead in your water. These counts cover the whole system, not your address. Ask your water system whether your home's line is on its inventory.

U.S. EPA, SDWIS/Fed Service Line Inventory report, data as of November 21, 2026

Historical results (2012-2019)

Lab results states sent EPA for 2012-2019, compiled by EPA for its Six-Year Review of drinking water rules, not for compliance decisions. They are more than six years old, so they may not reflect the water today, and they are never mixed with current results.

Sources

Data refreshed November 14, 2026

No government agency endorses TapDepth. See something wrong? Contact us

Have a website? Put a free water report like this on your site.