This is what Llano Grande Lake Park East reported to the state and EPA. It is not a test of the water at your tap, which your home's pipes and fixtures can change. Information only, not medical advice. Data sources and method
Depth Score · partial
Below limits, some above health goals
TapDepth's rating of public data, not a safety finding. As of Nov 2026, method 1.2. How the score works
From results reported by Llano Grande Lake Park East, City of Mercedes, sampled Jun 2025 to Aug 2026. Not a test of your tap.
- Health55%96
- Pipes20%Not included
Not in our data yet: utilities' lead service line inventories haven't been added.
- Track record15%0
- Everyday water10%Not included
No recent hardness or dissolved solids results.
How this score was worked out
Health
Each substance's average over its latest year of samples, compared with its legal limit and health goal. Up to 10 points off each. Volatile organic chemicals count as one group, by the worst one, and so do pesticides and industrial chemicals, and nitrate with nitrate + nitrite. Lead and copper use the 90th percentile of home tap samples and the action level.
| Substance | Average | Legal limit | Health goal | Rule | Points |
|---|---|---|---|---|---|
| Nitrate (as nitrogen) | 0.27 mg/L (1 sample, Jun 2025 to Jun 2025) | 10 mg/L | 10 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Nitrite (as nitrogen) | 0 mg/L (5 samples, Sep 2025 to Aug 2026) | 1 mg/L | 1 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Nitrate + nitrite (as nitrogen) | 0.27 mg/L (1 sample, Jun 2025 to Jun 2025) | 10 mg/L | 10 mg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Lead | 0 µg/L (1 sample, Jun 2026 to Jun 2026) | 15 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Arsenic | 2.55 µg/L (2 samples, Nov 2025 to Aug 2026) | 10 µg/L | 0 µg/L (EPA health goal (MCLG)) | Health goal is zero | −4 |
| Fluoride | 0.725 mg/L (2 samples, Nov 2025 to Aug 2026) | 4 mg/L | 4 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Benzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Carbon tetrachloride | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichlorobenzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 600 µg/L | 600 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,4-Dichlorobenzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 75 µg/L | 75 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichloroethane | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1-Dichloroethylene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 7 µg/L | 7 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| cis-1,2-Dichloroethylene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 70 µg/L | 70 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| trans-1,2-Dichloroethylene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Dichloromethane | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2-Dichloropropane | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Ethylbenzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 700 µg/L | 700 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Chlorobenzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Styrene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Tetrachloroethylene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Toluene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 1,000 µg/L | 1,000 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,2,4-Trichlorobenzene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 70 µg/L | 70 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1,1-Trichloroethane | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 200 µg/L | 200 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| 1,1,2-Trichloroethane | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 3 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Trichloroethylene | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 5 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Vinyl chloride | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 2 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Xylenes (total) | 0 µg/L (1 sample, Nov 2025 to Nov 2025) | 10,000 µg/L | 10,000 µg/L (EPA health goal (MCLG)) | At or below the health goal | Not counted (group) |
| Antimony | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 6 µg/L | 6 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Barium | 0.0671 mg/L (2 samples, Nov 2025 to Aug 2026) | 2 mg/L | 2 mg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Beryllium | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 4 µg/L | 4 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Cadmium | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 5 µg/L | 5 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Chromium (total) | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 100 µg/L | 100 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Cyanide | 35 µg/L (2 samples, Nov 2025 to Aug 2026) | 200 µg/L | 200 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Mercury (inorganic) | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 2 µg/L | 2 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Selenium | 2.55 µg/L (2 samples, Nov 2025 to Aug 2026) | 50 µg/L | 50 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
| Thallium | 0 µg/L (2 samples, Nov 2025 to Aug 2026) | 2 µg/L | 0.5 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
Track record
100, minus 25 for each health-based violation in the last 5 years (here 3), 10 for each from 5 to 10 years ago (3) and 3 for each missed or late test, report or notice (52). Boil water notices aren't in our data yet.
Everyday water
No recent hardness or dissolved solids results.
PFAS
PFAS are not counted until EPA's PFAS limits take effect. EPA currently lists April 2029 for PFOA and PFOS, and has proposed moving that to 2031. PFAS results are shown separately.
PFAS outlook: upcoming EPA limits
Not yet enforceable. EPA lists April 2029 and has proposed 2031.
PFOA and PFOS were not detected (below the lab's reporting limit) in the latest year of samples in our data.
Latest sample March 12, 2024. Highest sample point one-year average, counted the rule's way: 0 ng/L (3 samples at 1 sample point, Apr 2023 to Mar 2024).
Latest sample March 12, 2024. Highest sample point one-year average, counted the rule's way: 0 ng/L (3 samples at 1 sample point, Apr 2023 to Mar 2024).
Bars show the latest sample. The line marks EPA's upcoming limit of 4 ng/L each.
Reported by City of Mercedes, sampled March 12, 2024.
Averaged the way EPA's rule describes (each sample point's one-year average), using the results we have. The rule counts results below 4 ng/L (parts per trillion) as zero in that average. Our data may not include every sample point, and only regulators decide compliance.
The PFAS outlook is not a compliance finding and does not change the Depth Score. It covers PFOA and PFOS, the two PFAS limits EPA has said it plans to keep. Results from untreated source water are left out.
substances with a recent sample
in the latest samples
since Nov 2016
paperwork and monitoring, since Nov 2016
Current results
36 substancesSubstances with drinking water limits, from the last six years of samples. Highest recent sample shown.
- Nitrate (as nitrogen)0.27 mg/LReported by Llano Grande Lake Park East, sampled June 30, 2025.Sample point: point EP002 TRT-TAPWhat is nitrate?
- Nitrite (as nitrogen)Not detected (below 0.25 mg/L)Reported by Llano Grande Lake Park East, sampled August 19, 2026.Sample point: point EP002 TRT-TAPWhat is nitrite?
- Nitrate + nitrite (as nitrogen)0.27 mg/LReported by Llano Grande Lake Park East, sampled June 30, 2025.Sample point: point EP002 TRT-TAPWhat is nitrate + nitrite?
- LeadNot detectedReported by Llano Grande Lake Park East, sampled June 30, 2026.Sample point: 90th percentile of home tap samples the system collected, Jan 2026 to Jun 2026What is lead?
- Arsenic2.5 µg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.EPA's health goal for this substance is zero.Sample point: point EP001 TRT-TAPWhat is arsenic?
- Fluoride0.65 mg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is fluoride?
- BenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is benzene?
- Carbon tetrachlorideNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is carbon tetrachloride?
- 1,2-DichlorobenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,2-Dichlorobenzene?
- 1,4-DichlorobenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,4-Dichlorobenzene?
- 1,2-DichloroethaneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,2-Dichloroethane?
- 1,1-DichloroethyleneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,1-Dichloroethylene?
- cis-1,2-DichloroethyleneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is cis-1,2-Dichloroethylene?
- trans-1,2-DichloroethyleneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is trans-1,2-Dichloroethylene?
- DichloromethaneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is dichloromethane?
- 1,2-DichloropropaneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,2-Dichloropropane?
- EthylbenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is ethylbenzene?
- ChlorobenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is chlorobenzene?
- StyreneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is styrene?
- TetrachloroethyleneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is tetrachloroethylene?
- TolueneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is toluene?
- 1,2,4-TrichlorobenzeneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,2,4-Trichlorobenzene?
- 1,1,1-TrichloroethaneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,1,1-Trichloroethane?
- 1,1,2-TrichloroethaneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is 1,1,2-Trichloroethane?
- TrichloroethyleneNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is trichloroethylene?
- Vinyl chlorideNot detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is vinyl chloride?
- Xylenes (total)Not detected (below 0.5 µg/L)Reported by City of Mercedes, sampled November 5, 2025.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is xylenes?
- AntimonyNot detected (below 1 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is antimony?
- Barium0.0698 mg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is barium?
- BerylliumNot detected (below 0.8 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is beryllium?
- CadmiumNot detected (below 1 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is cadmium?
- Chromium (total)Not detected (below 10 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Total chromium includes chromium-3 and chromium-6. EPA's 100 µg/L limit covers the total, and there's no separate federal limit for chromium-6.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is chromium (total)?
- Cyanide70 µg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is cyanide?
- Mercury (inorganic)Not detected (below 0.4 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is mercury?
- Selenium5.1 µg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is selenium?
- ThalliumNot detected (below 0.4 µg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is thallium?
PFAS ("forever chemicals")
29 substancesEPA set limits for some PFAS in 2024. They aren't enforceable yet, so they're shown as upcoming limits and never in warning colors.
- PFOANot detected (below 4 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is PFOA?
- PFOSNot detected (below 4 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is PFOS?
- PFHxSNot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is PFHxS?
- PFNANot detected (below 4 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is PFNA?
- HFPO-DA (GenX)Not detected (below 5 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is genX (HFPO-DA)?
- PFBSNot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is PFBS?
- PFBANot detected (below 5 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFPeANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFHxANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFHpANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFDANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFUnANot detected (below 2 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFDoANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFTrDANot detected (below 7 ng/L)Reported by City of Mercedes, sampled October 17, 2023.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFTANot detected (below 8 ng/L)Reported by City of Mercedes, sampled October 17, 2023.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFPeSNot detected (below 4 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFHpSNot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFMPANot detected (below 4 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFMBANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- PFEESANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- NFDHANot detected (below 20 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- ADONANot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- 9Cl-PF3ONSNot detected (below 2 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- 11Cl-PF3OUdSNot detected (below 5 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- 4:2 FTSNot detected (below 3 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- 6:2 FTSNot detected (below 5 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- 8:2 FTSNot detected (below 5 ng/L)Reported by City of Mercedes, sampled March 12, 2024.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- NEtFOSAANot detected (below 5 ng/L)Reported by City of Mercedes, sampled October 17, 2023.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
- NMeFOSAANot detected (below 6 ng/L)Reported by City of Mercedes, sampled October 17, 2023.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is other PFAS?
Other monitored substances
2 substancesSubstances EPA asked systems to test for to decide future rules. Most have no limit yet.
- Sodium231 mg/LReported by Llano Grande Lake Park East, sampled March 29, 2026.Sample point: point DS01 DSTWQPWhat is sodium?
- Lithium57 µg/LReported by City of Mercedes, sampled October 17, 2023.Tested by City of Mercedes, which supplies this system.Sample point: Finished Tap (Plant - 208 S. Illinois)What is lithium?
Taste, smell and look
7 substancesGuidelines for taste and appearance. These are not health limits.
- Chloride263 mg/LReported by Llano Grande Lake Park East, sampled March 29, 2026.Sample point: point DS01 DSTWQPWhat is chloride?
- IronNot detected (below 0.05 mg/L)Reported by Llano Grande Lake Park East, sampled March 29, 2026.Sample point: point PBCU002 EWQPWhat is iron?
- Manganese0.0339 mg/LReported by Llano Grande Lake Park East, sampled March 29, 2026.Sample point: point DS01 DSTWQPWhat is manganese?
- Sulfate430 mg/LReported by Llano Grande Lake Park East, sampled March 29, 2026.Sample point: point DS01 DSTWQPWhat is sulfate?
- Aluminum0.0211 mg/LReported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is aluminum?
- SilverNot detected (below 0.01 mg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is silver?
- ZincNot detected (below 0.005 mg/L)Reported by City of Mercedes, sampled August 4, 2026.Tested by City of Mercedes, which supplies this system.Sample point: point EP001 TRT-TAPWhat is zinc?
These figures were reported by the water system to its regulators. They are not a test of the water at this address. Compliance is judged on averages over time, so one sample above a limit does not by itself mean a system is out of compliance. For a test of your own tap, use a state-certified laboratory. Units: mg/L is milligrams per liter, the same as parts per million (ppm); µg/L is micrograms per liter, the same as parts per billion (ppb); ng/L is nanograms per liter, the same as parts per trillion (ppt).
Violations since Nov 2016
Recorded by the state and EPAHealth-based
A drinking water limit or treatment requirement was not met.
- Violation recorded by the state for Oct 2022Lead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Violation recorded by the state for Apr 2022Lead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Violation recorded by the state for Mar 2022Lead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Violation recorded by the state for Oct 2019 to Feb 2020Lead and Copper Rule · Lead and Copper Rule · Status: resolved
- Violation recorded by the state for Apr 2019 to Feb 2020Lead and Copper Rule · Lead and Copper Rule · Status: resolved
- Violation recorded by the state for Mar 2019 to Feb 2020Lead and Copper Rule · Lead and Copper Rule · Status: resolved
Testing and reporting
A required test or report was missed or late. This is about paperwork and monitoring, and does not by itself mean the water was unsafe.
- Missed or late test or report (Apr 2026). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Missed or late test or report (Sep 2025). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Missed or late test or report (Jul 2025). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: unaddressed
- Missed or late test or report (Apr 2025 to Apr 2025). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Sep 2024 to Apr 2025). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Mar 2024 to Apr 2025). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
Show 31 more
- Missed or late test or report (Sep 2023 to Nov 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jul 2023 to Nov 2023). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: resolved
- Missed or late test or report (Apr 2023 to Jun 2023). Doesn't by itself mean the water was unsafeTTHM · Stage 2 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Apr 2023 to Jun 2023). Doesn't by itself mean the water was unsafeTotal Haloacetic Acids (HAA5) · Stage 2 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Apr 2023 to Jun 2023). Doesn't by itself mean the water was unsafeNitrite · Nitrate Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Jul 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Mar 2023). Doesn't by itself mean the water was unsafeTTHM · Stage 2 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Mar 2023). Doesn't by itself mean the water was unsafeTotal Haloacetic Acids (HAA5) · Stage 2 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Mar 2023). Doesn't by itself mean the water was unsafeNitrite · Nitrate Rule · Status: resolved
- Missed or late test or report (Jan 2023 to Jun 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Oct 2022 to Dec 2022). Doesn't by itself mean the water was unsafeChlorine · Stage 1 Disinfectants and Disinfection Byproducts Rule · Status: archived
- Missed or late test or report (Jul 2022 to Jul 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jul 2022 to Sep 2022). Doesn't by itself mean the water was unsafeChlorine · Stage 1 Disinfectants and Disinfection Byproducts Rule · Status: archived
- Missed or late test or report (Jul 2022 to Jan 2023). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: resolved
- Missed or late test or report (Jan 2022 to Jun 2022). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Dec 2021 to Nov 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Oct 2021). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: unaddressed
- Missed or late test or report (Jul 2021 to Jan 2023). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: resolved
- Missed or late test or report (Dec 2020 to Nov 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jul 2020 to Jan 2023). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: resolved
- Missed or late test or report (Mar 2020 to Nov 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Sep 2019 to Nov 2023). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jan 2019 to Jun 2019). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Dec 2018 to Mar 2020). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Oct 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: addressed
- Missed or late test or report (Jul 2018 to Dec 2019). Doesn't by itself mean the water was unsafeConsumer Confidence Rule · Consumer Confidence Rule · Status: resolved
- Missed or late test or report (Jun 2018 to Nov 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Jun 2018 to Nov 2018). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Oct 2017 to Feb 2019). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
- Missed or late test or report (Apr 2017 to Jun 2017). Doesn't by itself mean the water was unsafeChlorine · Stage 1 Disinfectants and Disinfection Byproducts Rule · Status: resolved
- Missed or late test or report (Dec 2016 to Mar 2020). Doesn't by itself mean the water was unsafeLead and Copper Rule · Lead and Copper Rule · Status: resolved
Notices and other requirements
A required notice to customers was missed or late.
- Public Notification Violation for NPDWR Violation (Aug 2023 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Aug 2023 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (May 2023 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Dec 2022 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Jun 2022 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Jun 2022 to Nov 2023)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
Show 9 more
- Public Notification Violation for NPDWR Violation (Sep 2020 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (May 2020 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (May 2020 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (May 2020 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Dec 2019 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Jun 2019 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Jun 2019 to Sep 2021)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Oct 2018 to Mar 2019)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
- Public Notification Violation for NPDWR Violation (Oct 2018 to Mar 2019)Public Notice · Public Notice Rule and Revised PN Rule · Status: resolved
On the map
Nearby water providers, colored by Depth ScoreLoading the map…
Open on the mapYearly water quality report
We don't have a link to this provider's yearly water quality report yet. Providers that serve homes send one to customers every year by July 1, and you can ask the provider for a copy.
Where the water comes from
Llano Grande Lake Park East buys water from:
- City of MercedesTX1080007
When this system has no result of its own for a substance, we show its supplier's and say so.
Service lines (pipes from the water main to buildings)
As reported by LLANO GRANDE LAKE PARK EAST to Texas, in EPA's records as of the third quarter of 2026: 0 lead, 0 galvanized needing replacement, 0 material not yet identified, 474 non-lead.
Galvanized needing replacement: galvanized lines that are or were connected to lead pipe, which the rule says must be replaced.
Non-lead counts may be incomplete: EPA doesn't require them until November 2027.
A lead or galvanized service line can add lead to water, but it doesn't mean there is lead in your water. These counts cover the whole system, not your address. Ask your water system whether your home's line is on its inventory.
U.S. EPA, SDWIS/Fed Service Line Inventory report, data as of November 21, 2026
Historical results (2012-2019)
Lab results states sent EPA for 2012-2019, compiled by EPA for its Six-Year Review of drinking water rules, not for compliance decisions. They are more than six years old, so they may not reflect the water today, and they are never mixed with current results.
- Total trihalomethanesLatest: 76.2 µg/L · 58 of 58 samples detected · highest 121 µg/L (November 5, 2012) · legal limit 80 µg/LWas above the legal limit in this sample (November 5, 2012).Historical result, sampled October 1, 2019. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by Texas to EPA.
Sources
Data refreshed November 14, 2026- Safe Drinking Water Information System (SDWIS/Fed), ECHO downloadsUS EPA, Safe Drinking Water Information System (SDWIS/Fed), via ECHO
- Service Line Inventory report (SDWIS Federal Reporting Services)U.S. EPA, SDWIS/Fed Service Line Inventory report
- Six-Year Review 4 compliance monitoring data (2012-2019)U.S. EPA, Six-Year Review 4 compliance monitoring data (2012-2019), as reported by state drinking water programs
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence dataUS EPA, UCMR 5 occurrence data
- Drinking Water Viewer: sample results (exported by hand)Texas Commission on Environmental Quality, Drinking Water Viewer data
No government agency endorses TapDepth. See something wrong? Contact us