This is what Santa Fe I.d. reported to the state and EPA. It is not a test of the water at your tap, which your home's pipes and fixtures can change. Information only, not medical advice. Data sources and method
Depth Score · partial
Below limits, some above health goals
TapDepth's rating of public data, not a safety finding. As of Nov 2026, method 1.0. How the score works
From results reported by Santa Fe I.d., sampled Jun 2025 to Sep 2026. Not a test of your tap.
- Health55%90
- Pipes20%Not included
Not in our data yet: utilities' lead service line inventories haven't been added.
- Track record15%100
- Everyday water10%63
How this score was worked out
Health
Each substance's average over its latest year of samples, compared with its legal limit and health goal. Up to 10 points off each. Volatile organic chemicals count as one group, by the worst one.
| Substance | Average | Legal limit | Health goal | Rule | Points |
|---|---|---|---|---|---|
| Arsenic | 0.46 µg/L (5 samples, Jun 2025 to Jun 2026) | 10 µg/L | 0.004 µg/L (California public health goal) | Between the health goal and the legal limit | −6.9 |
| Nitrate (as nitrogen) | 0.06 mg/L (5 samples, Jun 2025 to Jun 2026) | 10 mg/L | 10 mg/L (California public health goal) | At or below the health goal | 0 |
| Fluoride | 0.24 mg/L (5 samples, Jun 2025 to Jun 2026) | 2 mg/L | 1 mg/L (California public health goal) | At or below the health goal | 0 |
| Total trihalomethanes | 40.05 µg/L (21 samples, Nov 2025 to Sep 2026) | 80 µg/L | None set | No health goal: counts from half the limit | −3 |
Track record
100, minus 25 for each health-based violation in the last 5 years (here 0), 10 for each from 5 to 10 years ago (0) and 3 for each missed or late test, report or notice (0). Boil water notices aren't in our data yet.
Everyday water
Hardness (as calcium carbonate) 230 mg/L: 50. Total dissolved solids 542 mg/L: 75.
PFAS
PFAS are not counted until EPA's PFAS limits take effect. EPA currently lists April 2029 for PFOA and PFOS, and has proposed moving that to 2031. PFAS results are shown separately.
substances with a recent sample
in the latest samples
since Nov 2016
paperwork and monitoring, since Nov 2016
Current results
4 substancesSubstances with drinking water limits, from the last six years of samples. Highest recent sample shown.
- Arsenic1.2 µg/LReported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
- Nitrate (as nitrogen)Not detected (below 0.25 mg/L)Reported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
- Fluoride0.27 mg/LReported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
- Total trihalomethanes52 µg/LReported by Santa Fe I.d., sampled August 27, 2026.Sample point: RE BADGER FILTRATION PLANT
PFAS ("forever chemicals")
29 substancesEPA set limits for some PFAS in 2024. They aren't enforceable yet, so they're shown as upcoming limits and never in warning colors.
- PFOA3.4 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFOS2.3 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFHxSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFNANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- HFPO-DA (GenX)Not detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFBS3.6 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFBA4.3 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFPeA3.4 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFHxA3.5 ng/LReported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFHpANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFDANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFUnANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFDoANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFTrDANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFTANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFPeSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFHpSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFMPANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFMBANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- PFEESANot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- NFDHANot detected (below 20 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- ADONANot detected (below 3 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- 9Cl-PF3ONSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- 11Cl-PF3OUdSNot detected (below 5 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- 4:2 FTSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- 6:2 FTSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- 8:2 FTSNot detected (below 2 ng/L)Reported by Santa Fe I.d., sampled June 3, 2026.Sample point: RE BADGER FILTRATION PLANT
- NEtFOSAANot detected (below 5 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- NMeFOSAANot detected (below 6 ng/L)Reported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
Other monitored substances
3 substancesSubstances EPA asked systems to test for to decide future rules. Most have no limit yet.
- Lithium39.8 µg/LReported by Santa Fe I.d., sampled July 9, 2024.Sample point: 605 Regulating Reservoir
- Hardness (as calcium carbonate)300 mg/LReported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
- Sodium110 mg/LReported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
Taste, smell and look
1 substanceGuidelines for taste and appearance. These are not health limits.
- Total dissolved solids690 mg/LReported by Santa Fe I.d., sampled June 16, 2026.Sample point: RE BADGER FILTRATION PLANT
These figures were reported by the water system to its regulators. They are not a test of the water at this address. Compliance is judged on averages over time, so one sample above a limit does not by itself mean a system is out of compliance. For a test of your own tap, use a state-certified laboratory. Units: ng/L is nanograms per liter, the same as parts per trillion (ppt); µg/L is micrograms per liter, the same as parts per billion (ppb); mg/L is milligrams per liter, the same as parts per million (ppm).
Violations since Nov 2016
Recorded by the state and EPAHealth-based
A drinking water limit or treatment requirement was not met.
None recordedTesting and reporting
A required test or report was missed or late. This is about paperwork and monitoring, and does not by itself mean the water was unsafe.
None recordedYearly water quality report
Santa Fe I.d.'s 2025 report, also called a Consumer Confidence Report, lists what it found over the year and where its water comes from.
Where the water comes from
Santa Fe I.d. buys water from:
- San Diego County Water AuthorityCA3710042
When this system has no result of its own for a substance, we show its supplier's and say so.
Historical results (2012-2019)
Lab results states sent EPA for 2012-2019, compiled by EPA for its Six-Year Review of drinking water rules, not for compliance decisions. They are more than six years old, so they may not reflect the water today, and they are never mixed with current results.
- ArsenicLatest: not detected · 5 of 26 samples detected · highest 2.2 µg/L (September 17, 2014) · legal limit 10 µg/LHistorical result, sampled December 11, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
- Nitrate (as nitrogen)Latest: not detected · 1 of 26 samples detected · highest 0.86 mg/L (March 15, 2017) · legal limit 10 mg/LHistorical result, sampled December 11, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
- FluorideLatest: 0.27 mg/L · 26 of 26 samples detected · highest 0.38 mg/L (September 11, 2013) · legal limit 4 mg/LHistorical result, sampled December 11, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
- Total trihalomethanesLatest: 50 µg/L · 133 of 133 samples detected · highest 96 µg/L (June 14, 2017) · legal limit 80 µg/LWas above the legal limit in this sample (June 14, 2017).Historical result, sampled November 28, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
Sources
Data refreshed November 12, 2026- Drinking Water: Laboratory Water Quality Results (EDT library)State Water Resources Control Board, Division of Drinking Water
- Safe Drinking Water Information System (SDWIS/Fed), ECHO downloadsUS EPA, Safe Drinking Water Information System (SDWIS/Fed), via ECHO
- Six-Year Review 4 compliance monitoring data (2012-2019)U.S. EPA, Six-Year Review 4 compliance monitoring data (2012-2019), as reported by state drinking water programs
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence dataUS EPA, UCMR 5 occurrence data
No government agency endorses TapDepth. See something wrong? support@tapdepth.com