This is what Valenzuela Water System reported to the state and EPA. It is not a test of the water at your tap, which your home's pipes and fixtures can change. Information only, not medical advice. Data sources and method
Depth Score · partial
Averaged at or above a legal limit, above an action level, or a recent health violation
TapDepth's rating of public data, not a safety finding. As of Nov 2026, method 1.2. How the score works
From results reported by Valenzuela Water System, sampled Aug 2025 to Sep 2026. Not a test of your tap.
Capped at 49: Nitrate (as nitrogen) averaged at or above its legal limit (10 mg/L) in the latest year of samples.
- Health55%90
- Pipes20%Not included
Not in our data yet: utilities' lead service line inventories haven't been added.
- Track record15%71
- Everyday water10%Not included
No recent hardness or dissolved solids results.
How this score was worked out
Health
Each substance's average over its latest year of samples, compared with its legal limit and health goal. Up to 10 points off each. Volatile organic chemicals count as one group, by the worst one, and so do pesticides and industrial chemicals, and nitrate with nitrate + nitrite. Lead and copper use the 90th percentile of home tap samples and the action level.
| Substance | Average | Legal limit | Health goal | Rule | Points |
|---|---|---|---|---|---|
| Nitrate (as nitrogen) | 11.69 mg/L (53 samples, Sep 2025 to Sep 2026) | 10 mg/L | 10 mg/L (California public health goal) | At or above the legal limit | −10 |
| Total trihalomethanes | 6.5 µg/L (2 samples, Aug 2025 to Aug 2026) | 80 µg/L | None set | No health goal: counts from half the limit | 0 |
| Lead | 0 µg/L (1 sample, Dec 2025 to Dec 2025) | 15 µg/L | 0 µg/L (EPA health goal (MCLG)) | At or below the health goal | 0 |
Track record
100, minus 25 for each health-based violation in the last 5 years (here 0), 10 for each from 5 to 10 years ago (2) and 3 for each missed or late test, report or notice (3). Boil water notices aren't in our data yet.
Everyday water
No recent hardness or dissolved solids results.
PFAS
PFAS are not counted until EPA's PFAS limits take effect. EPA currently lists April 2029 for PFOA and PFOS, and has proposed moving that to 2031. PFAS results are shown separately.
PFAS outlook: upcoming EPA limits
Not yet enforceable. EPA lists April 2029 and has proposed 2031.
PFOA and PFOS were not detected (below the lab's reporting limit) in the latest year of samples in our data.
Latest sample July 17, 2025. Highest sample point one-year average, counted the rule's way: 0 ng/L (1 sample at 1 sample point, Jul 2025 to Jul 2025).
Latest sample July 17, 2025. Highest sample point one-year average, counted the rule's way: 0 ng/L (1 sample at 1 sample point, Jul 2025 to Jul 2025).
Bars show the latest sample. The line marks EPA's upcoming limit of 4 ng/L each.
Reported by Valenzuela Water System, sampled July 17, 2025.
Averaged the way EPA's rule describes (each sample point's one-year average), using the results we have. The rule counts results below 4 ng/L (parts per trillion) as zero in that average. Our data may not include every sample point, and only regulators decide compliance.
The PFAS outlook is not a compliance finding and does not change the Depth Score. It covers PFOA and PFOS, the two PFAS limits EPA has said it plans to keep. Results from untreated source water are left out.
substances with a recent sample
in the latest samples
since Nov 2016
paperwork and monitoring, since Nov 2016
Current results
5 substancesSubstances with drinking water limits, from the last six years of samples. Highest recent sample shown.
- ArsenicNot detected (below 1 µg/L)Reported by Valenzuela Water System, sampled March 16, 2026.Before treatment.Sample point: WELL 01What is arsenic?
- Nitrate (as nitrogen)5.5 mg/LReported by Valenzuela Water System, sampled September 28, 2026.Sample point: WELL 01 - NITRATE ION EXCHANGE & CL2What is nitrate?
- Fluoride0.3 mg/LReported by Valenzuela Water System, sampled March 16, 2026.Before treatment.Sample point: WELL 01What is fluoride?
- Total trihalomethanes5 µg/LReported by Valenzuela Water System, sampled August 10, 2026.Sample point: DBPR SampleWhat is total trihalomethanes?
- LeadNot detectedReported by Valenzuela Water System, sampled December 31, 2025.Sample point: 90th percentile of home tap samples the system collected, Jan 2023 to Dec 2025What is lead?
PFAS ("forever chemicals")
21 substancesEPA set limits for some PFAS in 2024. They aren't enforceable yet, so they're shown as upcoming limits and never in warning colors.
- PFOANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is PFOA?
- PFOSNot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is PFOS?
- PFHxS2.8 ng/LReported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is PFHxS?
- PFNANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is PFNA?
- HFPO-DA (GenX)Not detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is genX (HFPO-DA)?
- PFBS4.9 ng/LReported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is PFBS?
- PFBA2.9 ng/LReported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFPeA2.7 ng/LReported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFHxANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFHpANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFDANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFUnANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFDoANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFPeSNot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFHpSNot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFMPANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFMBANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- PFEESANot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- 4:2 FTSNot detected (below 2 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- 6:2 FTSNot detected (below 5 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
- 8:2 FTSNot detected (below 5 ng/L)Reported by Valenzuela Water System, sampled July 17, 2025.Before treatment.Sample point: WELL 01What is other PFAS?
Other monitored substances
2 substancesSubstances EPA asked systems to test for to decide future rules. Most have no limit yet.
- Hardness (as calcium carbonate)593 mg/LReported by Valenzuela Water System, sampled March 16, 2026.Before treatment.Sample point: WELL 01What is hardness?
- Sodium132 mg/LReported by Valenzuela Water System, sampled March 16, 2026.Before treatment.Sample point: WELL 01What is sodium?
Taste, smell and look
1 substanceGuidelines for taste and appearance. These are not health limits.
- Total dissolved solids1,010 mg/LReported by Valenzuela Water System, sampled March 16, 2026.Before treatment.Sample point: WELL 01What is total dissolved solids?
These figures were reported by the water system to its regulators. They are not a test of the water at this address. Compliance is judged on averages over time, so one sample above a limit does not by itself mean a system is out of compliance. For a test of your own tap, use a state-certified laboratory. Units: ng/L is nanograms per liter, the same as parts per trillion (ppt); mg/L is milligrams per liter, the same as parts per million (ppm); µg/L is micrograms per liter, the same as parts per billion (ppb).
Violations since Nov 2016
Recorded by the state and EPAHealth-based
A drinking water limit or treatment requirement was not met.
- Violation recorded by the state for May 2018 to May 2018Nitrate-Nitrite · Nitrate Rule · Status: archived
- Violation recorded by the state for Apr 2018 to Apr 2018Nitrate-Nitrite · Nitrate Rule · Status: archived
Testing and reporting
A required test or report was missed or late. This is about paperwork and monitoring, and does not by itself mean the water was unsafe.
- Missed or late test or report (May 2025 to May 2025). Doesn't by itself mean the water was unsafeRevised Total Coliform Rule · Revised Total Coliform Rule · Status: archived
- Missed or late test or report (Jun 2024 to Jun 2024). Doesn't by itself mean the water was unsafeRevised Total Coliform Rule · Revised Total Coliform Rule · Status: resolved
- Missed or late test or report (Mar 2020 to Mar 2020). Doesn't by itself mean the water was unsafeRevised Total Coliform Rule · Revised Total Coliform Rule · Status: resolved
On the map
Nearby water providers, colored by Depth ScoreLoading the map…
Open on the mapYearly water quality report
We don't have a link to this provider's yearly water quality report yet. Providers that serve homes send one to customers every year by July 1, and you can ask the provider for a copy.
Where the water comes from
No water purchases from another system are recorded.
Service lines (pipes from the water main to buildings)
As reported by VALENZUELA WATER SYSTEM to California, in EPA's records as of the third quarter of 2026: 0 lead, 0 galvanized needing replacement, 0 material not yet identified, 16 non-lead.
Galvanized needing replacement: galvanized lines that are or were connected to lead pipe, which the rule says must be replaced.
Non-lead counts may be incomplete: EPA doesn't require them until November 2027.
A lead or galvanized service line can add lead to water, but it doesn't mean there is lead in your water. These counts cover the whole system, not your address. Ask your water system whether your home's line is on its inventory.
U.S. EPA, SDWIS/Fed Service Line Inventory report, data as of November 21, 2026
Historical results (2012-2019)
Lab results states sent EPA for 2012-2019, compiled by EPA for its Six-Year Review of drinking water rules, not for compliance decisions. They are more than six years old, so they may not reflect the water today, and they are never mixed with current results.
- Nitrate (as nitrogen)Latest: 7.8 mg/L · 355 of 355 samples detected · highest 17.8 mg/L (May 14, 2018) · legal limit 10 mg/LWas above the legal limit in this sample (May 14, 2018).Historical result, sampled December 26, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
- Total trihalomethanesLatest: 18.95 µg/L · 5 of 5 samples detected · highest 18.95 µg/L (August 6, 2018) · legal limit 80 µg/LHistorical result, sampled August 6, 2018. More than six years old, so it may not reflect the water today. From EPA's Six-Year Review 4 data, as reported by California to EPA.
Sources
Data refreshed November 14, 2026- Drinking Water: Laboratory Water Quality Results (EDT library)State Water Resources Control Board, Division of Drinking Water
- Safe Drinking Water Information System (SDWIS/Fed), ECHO downloadsUS EPA, Safe Drinking Water Information System (SDWIS/Fed), via ECHO
- Service Line Inventory report (SDWIS Federal Reporting Services)U.S. EPA, SDWIS/Fed Service Line Inventory report
- Six-Year Review 4 compliance monitoring data (2012-2019)U.S. EPA, Six-Year Review 4 compliance monitoring data (2012-2019), as reported by state drinking water programs
No government agency endorses TapDepth. See something wrong? Contact us